iTero: Implant Case Setup, Scanning, and Ordering

The following article will walk you through how to set up a new implant case and send the order to Dandy.

Step 1: Select 'New Scan' 

Fill out your patient's first and last name, date of birth, and gender.

Step 2: Make selections for the order type

For ‘Procedure’ select 'Fixed Restorative' and for 'Type' select 'Implant Based.' 

You may select the tooth/teeth directly in the diagram and skip the 'type' selection.

Fill out the scan body manufacturer, implant manufacturer, and implant type. Input the restoration retention method, abutment type, and abutment material. Lastly, indicate the crown specification, material, and shade.

Step 3: Proceed to the scanning page

Click on the scanner in the ribbon on the top of your screen.

Step 4: Scan the prep site first

Center the prep within the viewfinder crosshair. Begin scanning with an occlusal view of the prep to visualize the margin. Roll from the lingual to the buccal of the prep. Roll from the distal to the mesial of the prep. Immediately review and fill any significant voids.

Step 5: Scan the lower and upper arch

The arch to begin scanning will be highlighted by the blue outline.

Follow an occlusal > lingual > buccal scan path.

Step 6: Capture the bite

Use swooping motions from the posterior to the canine, including 2 - 3mm of gingiva. Do this on the left and right side.

After the bite is obtained you will see a purple overlay on both sides indicating the bite is articulated.

Step 7: Process the scans

Select the magnifine glass from the ribbon at the top of your screen.

Review the scans before proceeding. 

Step 8: Submit the case

Click the mail icon and select 'send' when you see the pop up.

 